CCL
/ THERMOMETER TOOL
|
MAIN
FEATURES
- Nickel resistance
element.
- Fast temperature
response.
- High temperature
resolution.
- Two tools
in length of one.
- Fluid access
from four slots.
- CCL digitised
for transmission or storage.
- Direct diagnostics
communications with PC.
- Nan Gall addressable
bus interface.
- Simultaneous
deployment with other NGBUS tools.
- 0.1 second
update rate.
- API Data display
and presentation with Uni-SoftTM.
|
 |
APPLICATIONS
|
THERMOMETER
- Location of
fluid movement behind pipe/ casing.
- Location of
mud losses in drilling.
- Location of
fluid entries, gas leaks.
- Location of
depth of injection or production.
- Checking of
gas lift valves.
|
CCL
- Correlation
of depth using casing/tubing collars.
|
|
TOOL
SPECIFICATION
|
| Outside Diameter: |
1.375" (3.493cm) |
| Overall Length:
|
23.375" (59.37cm) |
| Weight: |
7lb (3.17kg) |
| Max Pressure: |
16,000psi (1104
bar) |
| Max Temperature: |
356°F (175) |
| Sensitivity Range: |
5 to 50°C
per track |
| Resolution: |
.01°C |
| Accuracy: |
+/-0.5°C |
| CCL Ref: |
3.38" from
bottom |
| Temp Ref: |
1.5" from
bottom |